Stylized graphic banner stating Safety Notices

Welcome to the Airgas Safety Notice Center*. Simply select from our list of manufacturer product safety notices to access more information about a product recall, product replacement program, product discontinuation or other important product safety updates. If you have any questions about a particular product safety notice, please contact our Customer Service department.

*The following notices are provided by the manufacturer.

    3M

  • Sealed-Blok™ SRLs produced from January 2022 to October 2024. Additionally, any devices repaired by 3M, or an authorized service center (ASC), during this timeframe may also be affected. Through laboratory testing, 3M has determined that in the event of a fall, these devices may not lock up as designed which could expose the worker to serious injury or death. There have been no reports of injuries associated with this issue.

    Due to this, we are sending out this Stop Use and Recall / Replace or Remediate Notice, so the select 3M DBI-SALA® Sealed-Blok™ Self-Retracting Lifelines are removed from service immediately. 3M is working towards having replacement product and remediation solutions available soon.

    Click to View or Download Document: select-3m-dbi-sala-sealed-blok-self-retracting-lifelines.pdf

    Click to View or Download Document: select-3m-dbi-sala-sealed-blok-self-retracting-lifeline-retrieval.pdf

  • Lifelines produced between November 17, 2023, and June 14, 2024. 3M has determined that in the event of a fall and under certain conditions, these devices may not lock up properly or prevent retrieval models from going into retrieval mode which could expose the worker to serious injury or death. There have been no reports of accidents or injuries associated with this issue.

    Due to this, we are sending out this Stop Use and Remediate notice, so the select 3M™ DBI-SALA® Ultra-Lok™ Self-Retracting Lifelines are removed from service immediately. Failure to read and follow all instructions associated with this Notice may result in serious injury or death of a user.

    Click to View or Download Document

  • It has come to our attention that some of the tubes may contain clear sealant despite being labeled as “white” on the packaging.

    Click to View or Download Document

  • Stop Use and Recall Notice to customers for the 3M™ PELTOR™ X4 Series Earmuffs manufactured between March 2020 through September 2022. 3M has identified that X4 earmuffs manufactured during this time period may develop cracks on the exterior surface of the cups.

    Click to View or Download Document

  • Stop use communication relating to combinations of 3M™ PELTOR™ X Series P5E Hard Hat Attached Electrically Insulated Earmuffs with various 3M™ and non-3M™head protection products.

    Click to View or Download Document

  • Safety products & PPE used by firefighters may contain small quantities of certain chemicals that meet the definition of per- and polyfluoroalkyl substances (PFAS) in some jurisdictions. May 8, 2023

  • 3M Fall Protection has identified a limited number of Protecta Harnesses where the harness webbing is not routed through the adjuster. This condition results in the adjuster not being able to be adjusted or does not lock in place after adjustments have been made.

    Click to View or Download Document

  • During an internal review, 3M Fall Protection has identified a potential manufacturing issue with a limited number of 3M™ DBI-SALA® ShockWave™ 2 Arc Flash Shock Absorbing Lanyards. This manufacturing issue could result in the lanyard not performing properly in the event of a fall, which could result in severe injury or death.

    Click to View or Download Document

  • We recently discovered the RCRA code was incorrect on the SDS for the 3M™ TB Quat Disinfectant (SKU 7100034339). If you need to dispose of unused product/expired product, continue to dispose of the product as specified on the label and on the updated SDS (DGN 24-9443-3 version 6, effective 3/23/2022). This revised SDS applies to all unused units that are still in your possession whether opened or unopened.

    Click to View or Download Document

  • During internal testing of certain 3M™ DBI-SALA® Delta™, ExoFit™, ExoFit™ Plus & ExoFit™ XP Cross Over Style Harness models, we found that a percentage of tested units did not meet the ANSI Z359.11, Section 3.2.2.3.1 dynamic requirement on the front (sternal) D-ring. This test and the resulting forces are not representative of what would be seen in real world application (i.e. when attached to a vertical cable sleeve with an energy absorbing device).

    Click to View or Download Document

  • The 3M DBI-SALA® Nano-Lok™ Self Retracting Lifeline with Anchor Hook to be assembled with an unformed top swivel eye rivet. An improperly formed rivet may become displaced from the top swivel eye. An unformed rivet may result in the SRL becoming detached from the anchor hook, which could result in severe injury or death.

    Click to View or Download Document

  • Recent testing of specific DBI-SALA® Delta™ and ExoFit™ XP Arc Flash harnesses have returned negative test results on some units. The Arc Flash Standard (ASTM F887) requires that all arc flash rated harnesses be subjected to an Arc Flash followed by a successful dynamic drop test.

    Click to View or Download Document

  • During internal testing, we found that a number of 3M™ Protecta® Vest-Style Positioning Harness AB17520 produced do not meet OSHA 1926.502 - Subpart M, Section D dynamic requirements for positioning on the side hip D-Rings.

    Click to View or Download Document

  • 3M Scott Fire & Safety has received a small number of reports of previously unused cylinder valves in the ACSi SCBA cylinders (equipped with 90° valve configuration) not flowing air when the handwheel is turned. This is the result of an incorrectly assembled cylinder valve.

    Click to View or Download Document

  • 3M Scott Fire & Safety has received a small number of reports of previously unused cylinder valves in the RIT-Pak Fast Attack cylinders (equipped with 90° valve configuration) not flowing air when the handwheel is turned. This is the result of an incorrectly assembled cylinder valve.

    Click to View or Download Document

  • A low percentage of these rope adjusters have a direction-of-use indicator label that is placed in the wrong direction. In the event of a fall from height, a rope adjuster used in the wrong direction may not arrest the fall and could result in serious injury or death to the worker.

    Click to View or Download Document

  • 3M Abrasive Systems Division (ASD) has recently identified potential safety concerns with 3M Flap Wheels 747D - lots numbered from #0304 to #1050. Use of affected products may potentially lead to health and safety concerns because flaps and parts of the core may detach during use.

    Click to View or Download Document

  • Immediate action required for 3M DBI-SALA Self-Rescue Descent Systems repaired or manufactured since the recall issued on August 6, 2020. Affected part numbers: 3320030, 31 & 37.

    Click to View or Download Document

  • 3M Fall Protection issued a Product Advisory on June 10, 2020 to address a potential cracking issue that may occur after repetitive descents of the training model of the 3M™ DBI-SALA® Self-Rescue Descent Systems, specifically P/N 3320037.

    Click to View or Download Document

  • This is not a recall and the 3M™ DBI-SALA® Self-Rescue Training Descent Systems P/N 3320037 remains safe to use for training purposes. This product advisory applies only to the training model RSQ (#3320037). No other models are affected.

    Click to View or Download Document

  • As part of 3M Fall Protections continued commitment to producing high quality safety and personal protective equipment, we conduct periodic testing of our products. Recent testing of specific DBI-SALA® Delta™ & Exofit XP™ Arc Flash harnesses have returned negative test results on some units. The Arc Flash Standard (ASTM F887) requires that all arc flash rated harnesses be subjected to an Arc Flash followed by a successful dynamic drop test. It should be noted that there is variability in Arc Flash testing of webbing based products. Although not fully understood, it can stem from several contributing factors including positioning, webbing gap to the test torso, environmental elements, arc path, input energy and other possible sources.

    Click to View or Download Document

  • Please immediately stop using all 3M™ Versaflo™ TR-6510N (OV/HE) and TR-6530N (OV/AG/HE) cartridges in your possession or control. The TR-6510N and TR-6530N cartridges are used with the 3M™ Versaflo™ TR-600 and TR-800 Powered Air Purifying Respirators (PAPRs). The TR-6510N cartridge is sold in a case of 5 and included in the 3M™ Versaflo™ Powered Air Purifying Respirator Painters Kit TR-800-PSK.

    Click to View or Download Document

  • 3M Fall Protection has determined that the 3M™ PROTECTA® Cobra Mobile/Manual Rope Grab AC202D is incorrectly stamped for use with 1/2 to 3/4 inch diameter rope on the exterior body of the unit. This Cobra Rope Grab is certified for use ONLY with 5/8 inch diameter polyester or polypropylene rope.

    Click to View or Download Document

  • 3M Fall Protection announces an immediate stop use and product recall of the 3M™ DBI-SALA® Nano-Lok™ edge and Wrap Back Twin-Leg Self Retracting Lifelines.

    Click to View or Download Document

  • 3M Abrasive Systems Division (ASD) has recently identified potential safety concerns with the following 3M™ Flap Discs 769F (Affected Products) and is issuing the attached Stop Use and Recall Notice regarding the Affected Products.

    Click to View or Download Document

  • 3M Fall Protection has learned of the possibility of a manufacturing defect in a dorsal d-ring utilized in ExoFit NEX™ harnesses manufactured between January 2016 and December 2018. Although there have been no reported incidents involving this condition, a dorsal d-ring with this defect will not support the load in a fall arrest event which could result in serious injury or death.

    Click to View or Download Document

  • 3M Fall Protection has received a series of inquiries regarding the use of dorsal D-ring extenders with Leading Edge SRL’s in environments where sharp edges are present. Examples of 3M dorsal D-ring extenders are shown below, but the concern applies to all dorsal D-ring extenders, regardless of the supplier/manufacturer:

    Click to View or Download Document

  • 3M Fall Protection has received reports that the aluminum reinforcement plate used in the seat sling on certain DBI-SALA ExoFit™, ExoFit XP™ (inc. Arc Flash), and ExoFit NEX™ (inc. Arc Flash) harnesses can become dislodged from the webbing.

    Click to View or Download Document

  • This letter is to inform you that 3M recently discovered that the sound localization performance of the 3M™ PELTOR™ COMTAC™ Hearing Defender headsets can be negatively affected by a wiring issue.

    Click to View or Download Document

  • 3M Fall Protection has detected a small quantity of DBI-SALA® 16 Ft. Talon™ Self Retracting Lifelines that are defective due to an assembly error. This notice only applies to the 16 ft version of the Talon; no other versions of the Talon are affected by this condition.

    Click to View or Download Document

  • 3M has identified a performance issue with certain models of 3M™ PELTOR™ X3 Earmuffs that were manufactured between March 2016 and May 2016, of which you should be aware.

    Click to View or Download Document

  • 3M has determined that selected production lots of the following three 3M™ Versaflo™ TR-600 Series cartridges may have been vacuum sealed too tightly, which may affect the performance of the center gasket due to deformation.

    Click to View or Download Document

  • At 3M, customer safety and confidence are high priorities. In light of the reported incidents and potential misuse scenarios, we have discontinued sale of the original Lad-Saf sleeve, and are voluntarily initiating a full recall of all original Lad-Saf sleeves.

    Click to View or Download Document

  • 3M Fall Protection (formerly Capital Safety) has identified a production issue with its Zorbit EnergyAbsorbers that creates a risk of serious injury or death for a user in the event of a fall from height.

    Click to View or Download Document

  • It has come to our attention that a limited number of 3M™ Particulate Respirator, 8233, N100 and 3M™ Particulate Respirator, 8293, P100 product that shipped recently from our facility do not meet the NIOSH specifications for N-100 class or P-100 class respirators.

    Click to View or Download Document

  • 3M has determined that select production lots and sizes of the 3M™ Protective Coverall 4570 may not meet a certain aspect of the EN-1149:5-2008 standard, specifically related to anti-static performance of the protective coverall.

    Click to View or Download Document

  • Ansell

  • These garments manufactured by an affiliate of Ansell, Peerless Canada, was intended to remain at our warehouse pending return to Peerless for inspection and review of a labelling issue, product was inadvertently shipped to a limited number of US-based Ansell customers. As a result, Ansell is withdrawing these garments with associated Lot Number from the market.

    Click to View or Download Document

  • DeWalt

  • Stanley Black & Decker has identified the hazard that the head of the sledgehammers can loosen prematurely on its first or early use and detach unexpectedly, posing an impact injury hazard to the user.

    Click to View or Download Document

  • In cooperation with the U.S. Consumer Product Safety Commission, we are recalling those products to address a rear guard assembly that can break or detach, posing an injury hazard to the user.

    Click to View or Download Document

  • Dräger

  • During routine surveillance testing it was discovered that the material used for the visor will not offer the required level of protection at extreme low temperatures and in some instances cracking of the visor may occur. Affected hood batches are detailed in the attached list

    Click to View or Download Document

  • Field Safety Corrective Action — Dräger X-am 8000 multi-gas detector with DrägerSensor XXS CO H2-CP, in conjunction with FirmWare (FW) version 01.04.11, can display false negative CO (carbon monoxide) concentrations when hydrogen is present.

    Click to View or Download Document

  • The indicator layer of Dräger Tubes n-butanol 10/a (81 01 861) of the affected batches may show a greenish coloring even in unused tubes, rather than the yellowish coloring described in the Instructions for Use.

    Click to View or Download Document

  • A number of our Drager Plus / PSS Series Lung Demand Valves (LDV) exhibiting reduced service life of the switch-off function due to a manufacturing error with the switch-off spring.

    Click to View or Download Document

  • Harrington

  • Harrington has become aware of a potential issue with CF model hoists manufactured between March 1, 2019 and October 7, 2019.

    Click to View or Download Document

  • HARTHealth

  • Ultratab Labs is conducting a voluntaiy recall of certain lots of OTC products manufactured between 10/31/2018 and 0 1/15/2020. See attached list of products and specific lot numbers.

    Click to View or Download Document

  • Honeywell

  • Product Stop Use Notice. Honeywell has identified an anomaly related to units manufactured from August 22, 2023, through October 23, 2023. This anomaly could prevent the product from properly supporting weight per specifications. The model/part number that could be affected is MFS-OGC1-02/30FT

    Click to View or Download Document

  • Our supplier notified us that appropriate production controls and documentation requirements were not followed when they produced this product. Therefore, Honeywell is warning customers to immediately stop using the Fendall Cartridge.

    Click to View or Download Document

  • We are alerting customers that lots of our two-tablet dose of APAP 250mg / Aspirin 250mg /Caffeine 65mg tablets in 1.375” x 2” packets of Paper/Poly film is being recalled. This voluntary class III recall has been initiated due to observed out of specification results for the Aspirin related compound Salicylic Acid in specified lots.

    Click to View or Download Document

  • While there have been no reported incidents related to this issue, out of an abundance of caution, we are sending this notice to provide guidance on a certain visual inspection that mustbe completed immediately and prior to use in order to ensure the proper safety performance of the SkyGrip System.

    Click to View or Download Document

  • Honeywell has announced an immediate stop use notice for the Honeywell Miller Heavy Duty Harness 650K, 850K, 060076, and 080007 Kevlar series ONLY when used for arc flash protection. Products included in this notice must be removed immediately from service when used for arc flash protection (product ordered for welding, standard fall protection and for non-arc flash activities can still be used).

    Click to View or Download Document

  • While there have been NO reported incidents due to this nonconformity, continued use of the product could result in serious injury or death.

    Click to View or Download Document

  • Testing has been completed to ensure that E3Point propane detectors are performing to our quality standards. Based on these findings, Honeywell Analytics is lifting the ship hold on all new orders for E3Point devices to be used for propane detection.

    Click to View or Download Document

  • We have recently informed the market of a deviation in quality affecting certain lot numbers of our Fibre Metal E2 Cap and North Peak A79 hard hats that may render them unable to provide the impact protection for which they were designed and certified.

    Click to View or Download Document

  • We have learned that fresh-air calibration of an oxygen (O2) sensor that has failed in the ToxiRAE Pro; QRAE 3; MultiRAE Series; AreaRAE Plus/Pro and MeshGuard EC monitors. This could result in a false reading, caused by a firmware anomaly.

    Click to View or Download Document

  • Hypertherm

  • WHypertherm Associates recently identified a batch of drag-style, Powermax SYNC® cartridges that had insufficient crimp depth on the shields. The insufficient crimp may lead to the loosening of the shield during use, possibly ending the life of the cartridge prematurely.

    Click to View or Download Document

  • Kent Precision Foods Group

  • KENT Precision Foods Group Inc. has reported to the Food and Drug Administration (FDA) that, out of an abundance of caution, it is voluntarily recalling the following Sqwincher branded items due to the potential presence of foreign materials

    Click to View or Download Document

  • Lincoln Electric

  • While a high percentage of the 1/8” Excalibur® 7018 MR cans in this Lot and Date Code contain the correct material, a portion may have unintentionally been manufactured using 309L stainless core wire.

    Click to View or Download Document

  • Miller Electric

  • Miller Electric Mfg. Co. has determined that a potential hazard may exist for Filtair 130 part #300595 portable fume extractors. Filtair 130s manufactured between August 2016 and March 24, 2017 with serial numbers MG335107D – MH105106D have a missing seal.

    Click to View or Download Document

  • Miller Electric Mfg. Co. has determined that a potential hazard exists due to the strain relief failure on the detachable power cord that is paired with the Maxstar 161 series product. We desire to recall/replace all affected detachable power cords part numbers 274989 (120V) and 274990 (240V).

    Click to View or Download Document

  • MSA

  • A one-time inspection procedure regarding the locking pin on MSA Latchways® Guided Type Fall Arresters (GTFAs) that were manufactured between February 16, 2021 and January 30, 2024.

    Click to View or Download Document

  • MSA has determined that PID sensors manufactured from March 2020 to and including June 2023 may not respond to gas after being turned on due to the lamp of the sensor not lighting upon startup and the Altair 5X PID will not display a PID lamp error.

    Click to View or Download Document

  • MSA is requesting that you perform the inspection outlined in this notice on MSA V-TEC and V-EDGE Self-Retracting Lifelines (SRLs) that were assembled prior to July, 2023, with the lifeline terminated improperly inside the unit. When the line is extended out near the end of the SRL, a V-TEC or V-EDGE SRL without a properly terminated lifeline may not arrest a fall.

    Click to View or Download Document

  • There is a new and additional required step to the inspection of your Fire Service G1 Self Contained Breathing Apparatus (SCBA). This is in response to a limited number of reports of bulging hoses for the G1 second stage regulator. The G1 SCBA operating manual contains instructions for visual inspections to be performed upon receipt, daily and after each use.

    Click to View or Download Document

  • MSA is advising all customers remove from service MSA Four Gas Calibration Cylinders (58L) marked with lot 239511 and cylinder part number 10045035. Follow the instructions in this notice before attempting to disconnect a cylinder from an accessory. Dispose of the cylinders in accordance with local regulations and contact MSA for a replacement.

    Click to View or Download Document

  • MSA is issuing this User Safety Notice to inform you that MSA has received field reports of a limited number of Latchways Standard Self-Retracting Lifelines (SRL) in which some internal bolts came loose. MSA has not received any reports of injuries associated with this condition. However, we are requesting that you perform the actions outlined in this notice.

    Click to View or Download Document

  • MSA is issuing this Inspection Notice to inform you that MSA has received field reports of a limited number of MSA V-EDGETM Leading Edge Self-Retracting Lifelines (SRL) that are missing the external shock absorber. MSA has not received any reports of injuries associated with this condition. However, we are requesting that you perform the inspection outlined in this notice.

    Click to View or Download Document

  • MSA has issued a User Notice for select batches of their Flexi-Filters. The part numbers affected are MSA818342 & MSA818343 and the material incorporated in these filters reduces longevity. Material from these batches was used in Flexi-Filters manufactured between May 15, 2020, and June 22, 2020. MSA performed testing and determined that, although the reduced longevity of the vendor's material may impact the filter performance over time, affected filters in the field have not reached their end life. MSA will provide replacements for the affected filters.

    Click to View or Download Document

  • An MSA vendor informed MSA of a reduced longevity for specific batches of the vendor’s material. The material is incorporated into certain part numbers of our Flexi-Filters®.

    Click to View or Download Document

  • MSA is issuing this Inspection Notice to inform you that MSA has received a limited number of field reports in which the lifeline in a WORKMAN MINI PFL did not retract after being fully extended. MSA has not received any reports of injuries associated with this condition. However, we are requesting that you perform the inspection outlined in this notice.

    Click to View or Download Document

  • MSA is issuing this Inspection Notice to inform you that MSA has identified isolated instances of unflared top eyelet rivets in MSA V-EdgeTM 2.4m Twin Leg Cable PFL. MSA has not received any reports of injuries associated with this condition. However, we are requesting that you perform the inspection outlined in this notice.

    Click to View or Download the recall notice

  • MSA is issuing this Safety Notice to inform you that MSA has identified the potential for reduced service life in select Advantage® 202 ABEK-P3 Cartridges. MSA has observed the condition in a small number of production samples and has not received any reports of injuries associated with this condition. However...

    Click to View or Download the recall notice

  • MSA is issuing this Inspection Notice to inform you that MSA has received a field report of an unflared center shaft in an MSA Latchways 10 ft. (3m) web PFL. MSA has not received any reports of injuries associated with this condition. However, we are requesting that you perform the inspection outlined in this notice.

    Click to View or Download the recall notice

  • This Safety Notice is issued to inform you that MSA recently received a report from CSA that samples of our Nuevo Wrap Safety Glasses did not pass CSA side impact testing.

    Click to View or Download the recall notice

  • MSA is issuing this update to the July 11, 2018 Safety Advisory to reflect that, for protective caps sold in the US or Canada, only protective caps with logos or stripes are affected. There is no change to the Safety Advisory for protective caps sold outside of the US and Canada.

    Click to View or Download the recall notice

  • This Safety Notice is issued to inform you that MSA recently received a report from CSA that samples of our Nuevo Wrap Safety Glasses did not pass CSA side impact testing.

    Click to View or Download the recall notice

  • This Safety Notice is issued to inform you that MSA received a field report from an end user regarding select MSA Gravity Welder Harnesses

    Click to View or Download the recall notice

  • MSA recently determined that white Topgard Protective Caps manufactured in January and February 2017 may not comply with the electrical insulation performance requirement and the helmet shell may crack during the ANSI/ISEA specified top impact test.

    Click to View or Download the recall notice

  • MSA recently determined that Super-V Protective Caps may not comply with the CSA (Canadian Standards Association) penetration performance requirement for a Type II (top and lateral) protective helmet

    Click to View or Download the recall notice

  • MSA recently received notification from Calgaz, one of our calibration gas suppliers, that they erroneously shipped approximately 110 cylinders that did not meet minimum service pressure requirements for a size 2AL cylinder.

    Click to View or Download the recall notice

    Click to View or Download the Handling Instructions

  • MSA has received field reports of SCBA cylinder male quick connect adapters cracking, which have resulted in a rapid loss of cylinder air.

    Click to View or Download Document

    Click to View or Download the July 19, 2016 Amendment

  • MSA recently learned that two lots of Advantage P100 Cartridges and one lot of Advantage GMAP100Cartridges were packaged in plastic bags identified as containing GME-P100 Cartridges.

    Click to View or Download Document

  • MSA is issuing this Safety Notice due to the potential inability to connect Quick-Fill and UAC fittings. These fittings are used on SCBA, portable air-suppl y rescue systems, and associated hose assemblies. We apologize for any inconvenience that this condit ion and the corrective actions outlined below may cause.

    Click to View or Download Document

    Click to View or Download the July 14, 2016 Amendment

  • MSA recently determined that there is a potential safety issue regarding GALAXY GX2 Automated Test Systems.

    Click to View or Download the recall notice

  • MSA recently determined that there is a potential safety issue regarding Ultima® XIR Gas Monitors.

    Click to View or Download the recall notice

  • MSA recently determined that there is a potential safety issue regarding OptimAir® TL OV/AG Cartridges (Part Numbers 10080454 for cartridge 6-pack, 10143422 for individual cartridge).

    Click to View or Download the recall notice

  • This User Notice is issued to inform you that MSA received field reports from end users regarding the exhalation valve stem in the G1 Facepiece and that, as a result of MSA’s findings related to these reports, you must take the actions outlined in this User Notice.

    Click to View or Download the recall notice

  • Milwaukee

  • During an internal review, Milwaukee has identified potential manufacturing issues with their 2767-20 1/2” High Torque Impact Wrench with Friction Ring. With the recent implementation of a new mechanical design in this model distinguished by “H96B” in the serial code, it has been discovered that this new design does not hold up to the Milwaukee name. Production will cease immediately and this model will no longer be sold. However, they will continue to produce H96A, the original design that has been on the market for years. 

    Click to View or Download Document

  • Phillips

  • Philips is issuing this recall due to a printing error on the foil pouch in which the cartridges are supplied. These cartridges fit the Philips HeartStart HS1, OnSite and Home Automated External Defibrillators (AEDs), but the AEDs themselves are not part of this action.

    Click to View or Download Document

  • PSG

  • This notice is intended to communicate product recall information regarding the Guardian Fall Protection Diablo Big Block Leading Edge Self-Retracting Lifeline. Due to a potential manufacturing defect over the period of February 2019 through February 2020, this product must be immediately removed from service and returned for inspection and repair.

    Click to View or Download Document

  • This notice is intended to communicate product recall information regarding the Guardian Fall Protection and Web Devices 3-Way Rescue and Retrieval self-retracting lifeline. Under certain conditions, braking forces may cause gear misalignment, potentially resulting in diminished rescue/retrieval functionality.

    Click to View or Download Document

  • This notice is intended to communicate product information regarding Guardian Fall Protection leading edge-compatible self-retracting lifelines (SRL-LE) that utilize a stainless steel or web lifeline. A small number of these SRLs were identified as non-compliant with ANSI Z359.14-14 and must immediately be removed from service.

    Click to View or Download Document

  • Responsive Respiratory

  • An important safety alert for a number of Tekno Valve and Sherwood branded oxygen cylinder valves. The aforementioned companies implemented a manufacturing process change in early 2021 and now lack a chamfer that is commonly used in the marketplace.

    Click to View or Download Document

  • Western

  • Western’s PF-4-XX and PF2-4-XX families of PTFE-lined flexible hoses with NPT fittings are rated for 3000 psi working pressure and the information tag attached to the hose should reflect this 3000 psi rating.

    Click to View or Download Document

  • Ziamatic

  • This is a voluntary recall of Ziamatic's "D" cylinder brackets, models QR-D-S and QR-TDS. The company has recently determined that either the bracket or the "D" cylinder may become detached when involved in a high-speed collision at a particular angle of impact. This issue was last reported in October 2019.

    Click to View or Download Document